archive-us.com » US » K » KUHNERSHAKER.US

Total: 105

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Kuhner Shaker, Inc. - Rack/Pilot
    50 60 Hz SMX1022 190 210V 50 60 Hz SMX1023 110 120V 50 60 Hz SMX1024 95 105V 50 60 Hz Top Options Options High capacity shaking machine for heavy loads suitable for temperature controlled rooms IQ OQ IQ OQ documentation IQ OQ Installation Qualification and Operation Qualification is an equipment qualification according to GMP procedure Kuhner offers this service which can also be carried out at the customer s premises Top Accessories Accessories High capacity shaking machine for heavy loads suitable for temperature controlled rooms Universal tray Fixed clamps Microtiter plates Sticky mats ISIS Software Interfaces Universal tray CU Order number SM3004 The universal tray can be fitted with clamps for Erlenmeyer flasks test tube holders microtiter plates or custom made holders to suit your requirements Rearranging these clamps and holders is quick and simple Clamps for Erlenmeyer flasks Test tube holders High capacity tube holders Holders for deep well microtiter plates Duetz System Sticky mats Top C tray 800 x 660mm with fixed clamps The clamps are riveted onto this tray and cannot be removed It offers maximum stability and will often hold a larger number of flasks than an universal tray These trays are available in a variety of flask clamp sizes from 25 to 6000ml Order Number Description Number of Clamps SM340025 C 25 ml 238 SM340050 C 50 ml 153 SM340100 C 100 ml 116 SM340125 C 125 ml 96 SM340150 C 150 ml 96 SM340200 C 200 ml 75 SM340250 C 250 ml 65 SM340300 C 300 ml 55 SM340500 C 500 ml 42 SM341000 C 1000 ml 24 SM341500 C 1500 ml 18 SM342000 C 2000 ml 15 SM343000 C 3000 ml 11 SM344000 C 4000 ml 8 SM345000 C 5000 ml 6 SM346000 C 6000 ml 6 Top C Tray for microtiter

    Original URL path: http://www.kuhnershaker.us/products/shaker/rack-pilot (2016-04-27)
    Open archived version from archive


  • Kuhner Shaker, Inc. - Single-Use
    meets all user needs Four mass flow controllers ensure highly accurate and reproducible gas mixing An integrated pressure sensor prevents over pressure in the bioreactor by reducing the gas flow in the first step 1 limit and shutting off the gas flow in the second step 2 limit Step limits can be freely programmed by the user Integrated air filters and back pressure valves ensure interference free and long operating times for the FlowCon Top Filter heater A height adjustable filter heater with up to two exhaust filters is installed above the cylindrical vessel Special emphasis has been placed on developing a user friendly unit The filter heater combats any water vapour condensation in the outlet air which might cause the membranes to block The temperature is monitored and controlled by ISIS X 8 0 software Filter heater Top Technical Data Technical data Orbital shaken bioreactor for disposable bags Shaker Mains Reader Box X Filter heater Control unit ISIS Software Pumps Gas mixing Shaker SMX7500 Shaker speed max 150 rpm Shaker diameter 50 mm orbital motion Weight approx 340 kg without liquid Accuracy absolute 0 1 rpm Setting digital 1 rpm Active brake 1300Wadjustable Interface CAN Bus RS232 Temperature up to 50 o C Cooling cooling coils are incorporated for connection to an external cooling system pressure 0 2bar Top Mains connection SMX1021 220 240 V 50 60 Hz SMX1023 110 120 V 50 60 Hz Top Reader Box X SMX7130 Oxygen sensor Optical measuring method Range 0 100 Accuracy 0 01 O 2 at 0 21 O 2 0 1 O 2 at 20 9 O 2 Drift 0 015 O 2 per day Temperature range up to 50 o C pH Sensor Optical measuring method Range 5 5 8 5 Accuracy 0 05 pH at pH 7 with one point calibration 0 10 pH at pH 7 with precalibration Drift 0 005 pH per day Temperature range up to 50 o C Top Filter heater SMX7120 Capacity 2 exhaust filters Temperature range Ambient temperature up to 70 o C monitored and controlled by ISIS Software Top Control unit Order number SMX1034 Weight 120 kg Monitor 15 touchscreen monitor Dimensions in mm Top ISIS Software Software for monitoring calibration controlling Monitoring O 2 pH shaking speed temperature Calibration pre calibrated sensors in bag Recalibration one point recalibration is possible Applicable XP Vista Win7 Win8 GMP 21 CFR Part 11 compliance audit trail Top Pumps 2 small pumps A B Watson Marlow 313VBM D Gear 10 Maximum speed 100 rpm Power 70 W Rollers 3 Tube 1 6 mm wall tubing Delivery pressure max 2bar 1 6 mm wall tubing Bore diameter mm Flow rates ml min at 100 rpm 0 5 3 4 0 8 7 1 6 27 3 2 100 4 8 220 6 4 360 8 0 500 1 big pump C Watson Marlow 520VBM R2 Gear 10 Maximum speed 400 rpm Power 70 W Rollers 2 Tube 2 4 mm wall tubing Delivery pressure max

    Original URL path: http://www.kuhnershaker.us/products/shaker/single-use (2016-04-27)
    Open archived version from archive

  • Kuhner Shaker, Inc. - Custom
    Ideal for climate controlled rooms Orbital shaking with maximum speed of 400 rpm Top Maximum flexibility through use of various vessels The superstructure can be custom built to suit the customer s application e g cell cultivation in containers of up to 100 liters or for particularly gentle mixing of solutions such as protein solutions in different types of vessels This machine is suitable for use in climate controlled rooms as the Kuhner direct drive generates very little heat The SR200 X is designed for maintenance free continuous operation with a maximum speed of 400rpm and a standard orbital shaking diameter of 50mm Other user specific diameters are possible Top Technical Data Technical data Flexible shaking machine for heavy loads that can be customized to your requirements Technical data ISIS Software Mains Technical data SMX2102 Speed 20 300 rpm Diameter 50 mm orbital motion Weight 340 kg Accuracy absolute 0 1 rpm Setting digital 1 rpm Active break adjustable Interface CAN Bus RS232 Loading maximum 100 kg Dimensions in mm Top ISIS Software Monitoring Shaking speed Accuracy absolute 0 30 o C 37 o C Principle of sensor Pt 100 Power of heating 1000W Power of cooling 155 270W Air circulation 300m3 h Top Mains Connection SMX1021 220 240V 50 60 Hz SMX1022 190 210V 50 60 Hz SMX1023 110 120V 50 60 Hz SMX1024 95 105V 50 60 Hz Top Options Options Flexible shaking machine for heavy loads that can be customized to your requirements IQ OQ IQ OQ documentation IQ OQ Installation Qualification and Operation Qualification is an equipment qualification according to GMP procedure Kuhner offers this service which can also be carried out at the customer s premises Top Accessories Accessories Flexible shaking machine for heavy loads that can be customized to your requirements ISIS Software Interfaces

    Original URL path: http://www.kuhnershaker.us/products/shaker/custom (2016-04-27)
    Open archived version from archive

  • Kuhner Shaker, Inc. - Advanced Applications
    Ons Flask pH and DO Measurement Respiration Measurement Duetz System Fed Batch SFR CTISens Bio FlowCon 2 3 4 COSBIOS Applied Technologies for Advanced Applications A valuable supplement Innovative products which are developed within Kuhner and in partnership with biotechnology companies and universities continuously expand the Kuhner portfolio In addition products developed externally are integrated into the Kuhner portfolio providing they bring qualitative benefits to shaken bioreactors Kuhner AG offers

    Original URL path: http://www.kuhnershaker.us/products/advanced-applications (2016-04-27)
    Open archived version from archive

  • Kuhner Shaker, Inc. - Kuhner Technology
    stand for high quality and cutting edge technology The direct drive specially developed by Kuhner combines uniform reliable performance with low energy consumption This drive is unique by allowing the shaking motion orbital or linear to be easily changed in the laboratory Equipment options and a wide range of accessories create an ever increasing number of application possibilities for our shakers The most important criteria for top quality incubator shakers

    Original URL path: http://www.kuhnershaker.us/products/technology (2016-04-27)
    Open archived version from archive

  • Kuhner Shaker, Inc. - SB200-x
    ensure highly accurate and reproducible gas mixing An integrated pressure sensor prevents over pressure in the bioreactor by reducing the gas flow in the first step 1 limit and shutting off the gas flow in the second step 2 limit Step limits can be freely programmed by the user Integrated air filters and back pressure valves ensure interference free and long operating times for the FlowCon Top Filter heater A height adjustable filter heater with up to two exhaust filters is installed above the vessel Special emphasis has been placed on developing a user friendly unit The filter heater combats any water vapor condensation in the outlet air which might cause the membranes to block The temperature is monitored and controlled by ISIS X 8 0 software Filter heater Top Technical Data Technical data Orbital shaken bioreactor for disposable bags Shaker Mains Reader Box X Filter heater Control unit ISIS Software Pumps Gas mixing Shaker SMX7100 Shaker speed max 80 rpm Shaker diameter 50 mm orbital motion Weight approx 400 kg without liquid Accuracy absolute 0 1 rpm Setting digital 1 rpm Active brake 1300Wadjustable Interface CAN Bus RS232 Temperature up to 50 o C Cooling cooling coils are incorporated for connection to an external cooling system pressure 0 2bar Dimensions in mm Top Mains connection SMX1021 220 240 V 50 60 Hz SMX1023 110 120 V 50 60 Hz SMX1024 95 105 V 50 60 Hz Top Reader Box X SMX7130 Oxygen sensor Optical measuring method Range 0 100 Accuracy 0 01 O 2 at 0 21 O 2 0 1 O 2 at 20 9 O 2 Drift 0 015 O 2 per day Temperature range up to 50 o C pH Sensor Optical measuring method Range 5 5 8 5 Accuracy 0 05 pH at pH 7 with one point calibration 0 10 pH at pH 7 with precalibration Drift 0 005 pH per day Temperature range up to 50 o C Top Filter heater SMX7120 Capacity 2 exhaust filters Temperature range Ambient temperature up to 70 o C monitored and controlled by ISIS Software Top Control unit Order number SMX7110 Weight 120 kg Monitor 15 touchscreen monitor Dimensions in mm Top ISIS Software Software for monitoring calibration controlling Monitoring O 2 pH shaking speed temperature Calibration pre calibrated sensors in bag Recalibration one point recalibration is possible Applicable XP Vista Win7 Win8 GMP 21 CFR Part 11 compliance audit trail Top Pumps 2 small pumps A B Watson Marlow 313VBM D Gear 10 Maximum speed 100 rpm Power 70 W Rollers 3 Tube 1 6 mm wall tubing Delivery pressure max 2bar 1 6 mm wall tubing Bore diameter mm Flow rates ml min at 100 rpm 0 5 3 4 0 8 7 1 6 27 3 2 100 4 8 220 6 4 360 8 0 500 1 big pump C Watson Marlow 520VBM R2 Gear 10 Maximum speed 400 rpm Power 70 W Rollers 2 Tube 2 4 mm wall tubing Delivery pressure

    Original URL path: http://www.kuhnershaker.us/products/shaker/single-use/sb200-x (2016-04-27)
    Open archived version from archive

  • Kuhner Shaker, Inc. - SR200-X
    drive Designed for heavy loads Ideal for climate controlled rooms Orbital shaking with maximum speed of 400 rpm Top Maximum flexibility through use of various vessels The superstructure can be custom built to suit the customer s application e g cell cultivation in containers of up to 100 liters or for particularly gentle mixing of solutions such as protein solutions in different types of vessels This machine is suitable for use in climate controlled rooms as the Kuhner direct drive generates very little heat The SR200 X is designed for maintenance free continuous operation with a maximum speed of 400rpm and a standard orbital shaking diameter of 50mm Other user specific diameters are possible Top Technical Data Technical data Flexible shaking machine for heavy loads that can be customized to your requirements Technical data ISIS Software Mains Technical data SMX2102 Speed 20 300 rpm Diameter 50 mm orbital motion Weight 340 kg Accuracy absolute 0 1 rpm Setting digital 1 rpm Active break adjustable Interface CAN Bus RS232 Loading maximum 100 kg Dimensions in mm Top ISIS Software Monitoring Shaking speed Accuracy absolute 0 30 o C 37 o C Principle of sensor Pt 100 Power of heating 1000W Power of cooling 155 270W Air circulation 300m3 h Top Mains Connection SMX1021 220 240V 50 60 Hz SMX1022 190 210V 50 60 Hz SMX1023 110 120V 50 60 Hz SMX1024 95 105V 50 60 Hz Top Options Options Flexible shaking machine for heavy loads that can be customized to your requirements IQ OQ IQ OQ documentation IQ OQ Installation Qualification and Operation Qualification is an equipment qualification according to GMP procedure Kuhner offers this service which can also be carried out at the customer s premises Top Accessories Accessories Flexible shaking machine for heavy loads that can be customized to

    Original URL path: http://www.kuhnershaker.us/products/shaker/custom/sr200-x (2016-04-27)
    Open archived version from archive

  • Kuhner Shaker, Inc. - Quality
    world in quality and technology for shaking machines The Kuhner shaker name stands for functionality reliability and durability A reputation for inventive ingenuity means Kuhner is setting today s standards To maintain these high standards Kuhner designs and builds many components in house and guarantees them for 5 years Naturally all processes are SN EN ISO 9001 certified Kuhner provides a personal and committed service and the customer is always

    Original URL path: http://www.kuhnershaker.us/about-us/about-us-quality (2016-04-27)
    Open archived version from archive



  •